{"product_id":"cognitive-performance-research-kit","title":"Cognitive Performance Research Kit","description":"\u003ch2\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe Cognitive Performance Research Kit is a ready-to-use multimodal research solution designed to investigate brain activity and physiological responses during demanding mental tasks. It supports experimental studies on attention, mental workload, decision-making, and cognitive stress by combining cortical hemodynamic monitoring with synchronized autonomic measurements. \u003cbr\u003eAt its core, the integrated fNIRS sensor measures changes in cortical blood oxygenation, providing objective insight into prefrontal activation associated with executive function and sustained attention. Complementary physiological signals enable the assessment of autonomic responses linked to cognitive load, allowing integrated analysis of brain and body dynamics. \u003cbr\u003eThis kit is intended for researchers and advanced users in cognitive neuroscience, human factors, and performance research conducting controlled or applied experimental studies. PLUX software is available for real-time signal visualization and structured data recording.\u003c\/p\u003e\n\u003ch2\u003eWhat's Included?\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e1x wireless 4-channel hub\u003c\/li\u003e\n\u003cli\u003eECG sensor\u003c\/li\u003e\n\u003cli\u003eEDA sensor\u003c\/li\u003e\n\u003cli\u003eRIP sensor\u003c\/li\u003e\n\u003cli\u003efNIRS sensor\u003c\/li\u003e\n\u003cli\u003e1x Bluetooth dongle\u003c\/li\u003e\n\u003cli\u003e1x medical-grade charger\u003c\/li\u003e\n\u003cli\u003e24x pre-gelled electrodes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eResources\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/support.pluxbiosignals.com\/wp-content\/uploads\/2021\/10\/biosignalsplux-4-Channel-Hub-Datasheet.pdf\" title=\"biosignalsplux 4-channel hub datasheet with technical specifications (PDF)\"\u003e4-Channel Hub Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/support.pluxbiosignals.com\/wp-content\/uploads\/2021\/11\/biosignalsplux_User_Manual.pdf\" title=\"biosignalsplux user manual with setup and operation instructions (PDF)\"\u003ebiosignalsplux User Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/support.pluxbiosignals.com\/wp-content\/uploads\/2021\/11\/biosignalsplux_Quickstart_Guide.pdf\" title=\"biosignalsplux quickstart guide for initial setup (PDF)\"\u003eBiosignalsplux Quickstart Guide\u003c\/a\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eResearch Evidence \u0026amp; Applications\u003c\/h2\u003e\n\u003cp data-start=\"722\" data-end=\"943\"\u003e\u003cstrong data-start=\"722\" data-end=\"827\"\u003eAttention Classification Based on Biosignals during Standard Cognitive Tasks for Occupational Domains\u003c\/strong\u003e\u003cbr data-start=\"827\" data-end=\"830\"\u003eGamboa, P., Varandas, R., Rodrigues, J., Cepeda, C., Quaresma, C., \u0026amp; Gamboa, H. Published in \u003cem data-start=\"923\" data-end=\"934\"\u003eComputers\u003c\/em\u003e in 2022.\u003c\/p\u003e\n\u003cp data-start=\"945\" data-end=\"1146\"\u003eThe study used PLUX data acquisiton devices to collect physiological data during standard cognitive tasks for attention classification, including ECG, EEG, EDA, fNIRS, RIP and accelerometer data.\u003c\/p\u003e\n\u003cp data-start=\"1148\" data-end=\"1204\"\u003eRead publication \u003ca rel=\"noopener\" title=\"cognitive performance study plux biosignals\" href=\"https:\/\/www.mdpi.com\/2073-431X\/11\/4\/49\" target=\"_blank\"\u003ehere\u003c\/a\u003e.\u003cmeta charset=\"utf-8\"\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003cp data-start=\"6903\" data-end=\"7092\"\u003e\u003cstrong data-start=\"6903\" data-end=\"7007\"\u003ePredicting Driver’s Mental Workload Using Physiological Signals: A Functional Data Analysis Approach\u003c\/strong\u003e\u003cbr data-start=\"7007\" data-end=\"7010\"\u003eBiondi, F. N., Rodriguez, E. F., et al. Published in \u003cem data-start=\"7063\" data-end=\"7083\"\u003eApplied Ergonomics\u003c\/em\u003e in 2024.\u003c\/p\u003e\n\u003cp data-start=\"7094\" data-end=\"7250\"\u003eThe study used biosignalsplux ECG, EMG, EDA and EEG sensors to collect physiological data during simulated driving tasks and predict driver mental workload.\u003c\/p\u003e\n\u003cp data-start=\"7252\" data-end=\"7311\"\u003eRead publication \u003ca rel=\"noopener\" href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/38521001\/\" target=\"_blank\"\u003ehere\u003c\/a\u003e.\u003c\/p\u003e\n\u003chr\u003e\n\u003cp data-start=\"7341\" data-end=\"7512\"\u003e\u003cstrong data-start=\"7341\" data-end=\"7452\"\u003ePhysioLab - A Multivariate Physiological Signal Analysis and Interpretation Toolbox for the Study of Effort\u003c\/strong\u003e\u003cbr data-start=\"7452\" data-end=\"7455\"\u003ePublished in \u003cem data-start=\"7468\" data-end=\"7503\"\u003eMultimedia Tools and Applications\u003c\/em\u003e in 2018.\u003c\/p\u003e\n\u003cp data-start=\"7514\" data-end=\"7677\"\u003eThe study used the biosignalplux toolkit with EDA, ECG and EMG sensors to analyse physiological responses related to effort, cognitive load and physical activity.\u003c\/p\u003e\n\u003cp data-start=\"7679\" data-end=\"7738\"\u003eRead publication \u003ca href=\"https:\/\/doi.org\/10.1007\/s11042-017-5069-z\" rel=\"noopener\" target=\"_blank\"\u003ehere.\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2\u003eFrequently Asked Questions (FAQs)\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat exactly is included in the Cognitive Performance Research Kit?\u003c\/strong\u003e\u003cbr\u003eThe Cognitive Performance Research Kit includes a complete biosignalsplux setup for synchronized physiological data acquisition, based on a 4-channel wireless hub and a predefined set of sensors (ECG, EDA, RIP and fNIRS). \u003cbr\u003eIt also includes all essential and sensor-specific accessories required for proper data acquisition, ensuring a ready-to-use setup without additional system integration.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I access raw physiological data from all sensors?\u003c\/strong\u003e\u003cbr\u003eYes. The kit provides access to raw physiological data from all included sensors.\u003cbr\u003eUsing PLUX software tools, users can visualize and record biosignals in real time, supporting the analysis of physiological and cognitive responses during demanding mental tasks.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs the kit modular or fixed, and can sensors be added or removed?\u003c\/strong\u003e\u003cbr\u003eThe kit is delivered as a predefined configuration, while remaining compatible with the modular biosignalsplux ecosystem. Users can add, remove or replace sensors as needed, with support for up to 4 sensors simultaneously using the included hub.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs this system suitable for both academic and applied research?\u003c\/strong\u003e\u003cbr\u003eYes. The kit is designed to support both academic and applied research in cognitive neuroscience, human factors and performance studies. It can be used in controlled laboratory environments as well as in applied scenarios where cognitive performance and mental workload need to be assessed.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan the system be used for real-time monitoring during cognitive tasks?\u003c\/strong\u003e\u003cbr\u003eYes. The kit supports real-time monitoring of physiological signals during cognitive tasks. Users can visualize signals as they are acquired, enabling immediate observation of responses associated with cognitive load and task demands.\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"PLUX Biosignals","offers":[{"title":"Default Title","offer_id":57335390273861,"sku":null,"price":3396.25,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0595\/1068\/5887\/files\/1800-CognitivePerformanceResearch-00-ProductDetailsPage.jpg?v=1778059782","url":"https:\/\/www.pluxbiosignals.com\/en-fr\/products\/cognitive-performance-research-kit","provider":"PLUX Biosignals","version":"1.0","type":"link"}