{"title":"Ready-To-Use Biosignal Research Kits","description":"\u003cp data-end=\"1045\" data-start=\"561\"\u003e\u003cmeta charset=\"utf-8\"\u003ePLUX Ready-To-Use Kits are pre-configured biosignal monitoring bundles for physiological data acquisition in research, education and applied study environments. Each kit combines \u003ca rel=\"noopener\" title=\"biosignalsplux range\" href=\"\/collections\/biosignalsplux\" target=\"_blank\"\u003ebiosignalsplux\u003c\/a\u003e hardware with selected sensors to collect synchronized physiological signals for applications such as stress and fatigue research, cardiorespiratory monitoring, sleep research, cognitive performance studies and human performance assessment.\u003c\/p\u003e","products":[{"product_id":"automotive-human-performance-kit","title":"Automotive Human Performance Kit","description":"\u003ch2\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe Automotive Human Performance Kit is a ready-to-use physiological data acquisition solution for research focused on human performance in automotive environments. It consists of an \u003ca href=\"https:\/\/www.pluxbiosignals.com\/products\/8-channel-biosignals-kit\"\u003e8-Channel biosignalsplux kit\u003c\/a\u003e combined with a pre-defined set of physiological sensors, enabling synchronized and reliable hardware-based data collection during driving-related studies. Users can access PLUX’s software for real-time signal visualization, with optional add-ons for signal processing. \u003cbr\u003eThis kit is intended for automotive R\u0026amp;D teams, human factors researchers and mobility research laboratories conducting experimental studies in driving simulators or real-world conditions. It supports applied research scenarios where objective physiological data is required to characterize driver state under demanding tasks. Using this kit, researchers can assess driver stress, fatigue and physiological workload through synchronized cardiac, respiratory, autonomic and movement-related signals, providing objective insight into the driver’s physiological response during automotive research experiments.\u003c\/p\u003e\n\u003ch2\u003eWhat's Included?\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e1x wireless 8-channel hub\u003c\/li\u003e\n\u003cli\u003eECG sensor\u003c\/li\u003e\n\u003cli\u003eRIP sensor\u003c\/li\u003e\n\u003cli\u003e2 EDA sensors\u003c\/li\u003e\n\u003cli\u003eACC sensor\u003c\/li\u003e\n\u003cli\u003e1x Bluetooth dongle\u003c\/li\u003e\n\u003cli\u003e1x medical-grade charger\u003c\/li\u003e\n\u003cli\u003e30x pre-gelled electrodes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eResources\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca title=\"biosignalsplux 8-channel hub datasheet with technical specifications (PDF)\" href=\"https:\/\/support.pluxbiosignals.com\/wp-content\/uploads\/2021\/10\/biosignalsplux-4-Channel-Hub-Datasheet.pdf\"\u003e8-channel Hub Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca title=\"biosignalsplux user manual with setup and operation instructions (PDF)\" href=\"https:\/\/support.pluxbiosignals.com\/wp-content\/uploads\/2021\/11\/biosignalsplux_User_Manual.pdf\"\u003eBiosignalsplux User Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca title=\"biosignalsplux quickstart guide for initial setup (PDF)\" href=\"https:\/\/support.pluxbiosignals.com\/wp-content\/uploads\/2021\/11\/biosignalsplux_Quickstart_Guide.pdf\"\u003eBiosignalsplux Quickstart Guide\u003c\/a\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eResearch Evidence \u0026amp; Applications\u003c\/h2\u003e\n\u003csection data-turn=\"assistant\" data-scroll-anchor=\"false\" data-testid=\"conversation-turn-94\" data-turn-id=\"request-69fb1079-d660-832a-8261-16cbb2dc5b5c-13\" dir=\"auto\" class=\"text-token-text-primary w-full focus:outline-none [--shadow-height:45px] has-data-writing-block:pointer-events-none has-data-writing-block:-mt-(--shadow-height) has-data-writing-block:pt-(--shadow-height) [\u0026amp;:has([data-writing-block])\u0026gt;*]:pointer-events-auto [content-visibility:auto] supports-[content-visibility:auto]:[contain-intrinsic-size:auto_100lvh] R6Vx5W_threadScrollVars scroll-mb-[calc(var(--scroll-root-safe-area-inset-bottom,0px)+var(--thread-response-height))] scroll-mt-[calc(var(--header-height)+min(200px,max(70px,20svh)))]\"\u003e\n\u003cdiv class=\"text-base my-auto mx-auto pb-10 [--thread-content-margin:var(--thread-content-margin-xs,calc(var(--spacing)*4))] @w-sm\/main:[--thread-content-margin:var(--thread-content-margin-sm,calc(var(--spacing)*6))] @w-lg\/main:[--thread-content-margin:var(--thread-content-margin-lg,calc(var(--spacing)*16))] px-(--thread-content-margin)\"\u003e\n\u003cdiv class=\"[--thread-content-max-width:40rem] @w-lg\/main:[--thread-content-max-width:48rem] mx-auto max-w-(--thread-content-max-width) flex-1 group\/turn-messages focus-visible:outline-hidden relative flex w-full min-w-0 flex-col agent-turn\"\u003e\n\u003cdiv class=\"flex max-w-full flex-col gap-4 grow\"\u003e\n\u003cdiv class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal outline-none keyboard-focused:focus-ring [.text-message+\u0026amp;]:mt-1\" data-message-model-slug=\"gpt-5-5-thinking\" dir=\"auto\" data-turn-start-message=\"true\" data-message-id=\"152c7090-308d-461b-a26b-1b8e7dff6c56\" data-message-author-role=\"assistant\" tabindex=\"0\"\u003e\n\u003cdiv class=\"flex w-full flex-col gap-1 empty:hidden\"\u003e\n\u003cdiv class=\"markdown prose dark:prose-invert w-full wrap-break-word dark markdown-new-styling\"\u003e\n\u003cp data-end=\"7993\" data-start=\"7804\"\u003e\u003cstrong data-end=\"7908\" data-start=\"7804\"\u003ePredicting Driver’s Mental Workload Using Physiological Signals: A Functional Data Analysis Approach\u003c\/strong\u003e\u003cbr data-end=\"7911\" data-start=\"7908\"\u003eBiondi, F. N., Rodriguez, E. F., et al. Published in \u003cem data-end=\"7984\" data-start=\"7964\"\u003eApplied Ergonomics\u003c\/em\u003e in 2024.\u003c\/p\u003e\n\u003cp data-end=\"8164\" data-start=\"7995\"\u003eThe study used biosignalsplux ECG, EMG, EDA and EEG sensors to collect physiological data from 41 participants in a driving simulator and predict driver mental workload.\u003c\/p\u003e\n\u003cp data-end=\"8225\" data-start=\"8166\"\u003eRead publication \u003ca rel=\"noopener\" href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/38521001\/\" target=\"_blank\"\u003ehere.\u003c\/a\u003e\u003c\/p\u003e\n\u003chr data-end=\"8230\" data-start=\"8227\"\u003e\n\u003cp data-end=\"8446\" data-start=\"8255\"\u003e\u003cstrong data-end=\"8374\" data-start=\"8255\"\u003eRevealing driver psychophysiological response to emergency braking in distracted driving based on field experiments\u003c\/strong\u003e\u003cbr data-end=\"8377\" data-start=\"8374\"\u003ePublished in \u003cem data-end=\"8437\" data-start=\"8390\"\u003eJournal of Intelligent and Connected Vehicles\u003c\/em\u003e in 2022.\u003c\/p\u003e\n\u003cp data-end=\"8619\" data-start=\"8448\"\u003eThe study used biosignalsplux ECG, EMG and EDA sensors to collect psychophysiological data during real-road emergency braking experiments in distracted driving conditions.\u003c\/p\u003e\n\u003cp data-end=\"8680\" data-start=\"8621\"\u003eRead publication \u003ca rel=\"noopener\" href=\"https:\/\/doi.org\/10.1108\/JICV-06-2022-0024\" target=\"_blank\"\u003ehere\u003c\/a\u003e.\u003ca class=\"decorated-link cursor-pointer\" rel=\"noopener\" data-end=\"8680\" data-start=\"8639\"\u003e\u003cspan class=\"ms-0.5 inline-block align-middle leading-none\" aria-hidden=\"true\"\u003e\u003csvg class=\"block h-[0.75em] w-[0.75em] stroke-current stroke-[0.75]\" data-rtl-flip=\"\" aria-hidden=\"true\" height=\"20\" width=\"20\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"\u003e\u003cuse fill=\"currentColor\" href=\"\/cdn\/assets\/sprites-core-6d2147a0.svg#304883\"\u003e\u003c\/use\u003e\u003c\/svg\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003chr data-end=\"8685\" data-start=\"8682\"\u003e\n\u003cp data-end=\"8708\" data-start=\"8687\"\u003e\u003cstrong data-end=\"8838\" data-start=\"8710\"\u003eCBmeter study: protocol for assessing the predictive value of peripheral chemoreceptor overactivation for metabolic diseases\u003c\/strong\u003e\u003cbr data-end=\"8841\" data-start=\"8838\"\u003eConde, S. V., Sacramento, J. F., Guarino, M. P., Gonzalez, C., Monteiro, E. C., Moura, M. J., et al. Published in \u003cem data-end=\"8965\" data-start=\"8955\"\u003eBMJ Open\u003c\/em\u003e in 2021.\u003c\/p\u003e\n\u003cp data-end=\"9191\" data-start=\"8976\"\u003eThe study used biosignalsplux ECG, RIP respiration and SpO₂ sensors as part of a clinical physiological monitoring protocol, supporting the use of PLUX hardware for high-quality ECG and respiratory data acquisition.\u003c\/p\u003e\n\u003cp data-is-only-node=\"\" data-is-last-node=\"\" data-end=\"9252\" data-start=\"9193\"\u003eRead publication \u003ca rel=\"noopener\" href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/34446475\/\" target=\"_blank\"\u003ehere\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003ch2\u003eFrequently Asked Questions (FAQs)\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat exactly is included in the Automotive Human Performance Kit?\u003c\/strong\u003e\u003cbr\u003eThe Automotive Human Performance Kit includes a complete biosignalsplux setup for synchronized physiological data acquisition in automotive research scenarios, based on an 8-channel wireless hub and a predefined set of sensors (ECG, RIP, EDA and ACC). \u003cbr\u003eIt also includes all essential accessories for data acquisition, such as communication, power and sensor-specific components, ensuring a ready-to-use configuration without the need for additional system integration.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs the kit modular or fixed, and can sensors be added or removed?\u003cbr\u003e\u003c\/strong\u003eThe kit is delivered as a predefined configuration optimized for automotive research, while remaining fully compatible with the modular biosignalsplux ecosystem. Users can add, remove or replace sensors as needed, with support for up to 8 sensors simultaneously using the included 8-channel hub.\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs this system suitable for academic and industrial research?\u003cbr\u003e\u003c\/strong\u003eYes. The Automotive Human Performance Kit is designed to support both academic and industrial research in automotive and human performance studies. \u003cbr\u003eIt enables the acquisition of synchronized, objective physiological data across multiple signal types, supporting use in laboratory experiments, driving simulators and real-world testing environments.\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I access raw physiological data from all sensors?\u003c\/strong\u003e\u003cbr\u003eYes. The kit provides access to raw physiological data from all included sensors.\u003cbr\u003eUsing PLUX software tools such as Biosignals Studio or available APIs, users can visualize, record and process biosignals in real time or integrate them into custom analysis workflows.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs the kit suitable for real-world driving studies as well as simulators?\u003c\/strong\u003e\u003cbr\u003eYes. The kit is designed for use in both driving simulators and real-world driving studies. \u003cbr\u003eIts wireless, battery-powered design supports several hours of continuous data acquisition (up to ~10h depending on configuration), enabling reliable physiological data collection in both controlled and in-vehicle environments.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"biosignalsplux","offers":[{"title":"Default Title","offer_id":57334875816261,"sku":null,"price":5092.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0595\/1068\/5887\/files\/1800-Automotive-Human-Performance-00-ProductDetailsPage.jpg?v=1778059481"},{"product_id":"cognitive-performance-research-kit","title":"Cognitive Performance Research Kit","description":"\u003ch2\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe Cognitive Performance Research Kit is a ready-to-use multimodal research solution designed to investigate brain activity and physiological responses during demanding mental tasks. It supports experimental studies on attention, mental workload, decision-making, and cognitive stress by combining cortical hemodynamic monitoring with synchronized autonomic measurements. \u003cbr\u003eAt its core, the integrated fNIRS sensor measures changes in cortical blood oxygenation, providing objective insight into prefrontal activation associated with executive function and sustained attention. Complementary physiological signals enable the assessment of autonomic responses linked to cognitive load, allowing integrated analysis of brain and body dynamics. \u003cbr\u003eThis kit is intended for researchers and advanced users in cognitive neuroscience, human factors, and performance research conducting controlled or applied experimental studies. PLUX software is available for real-time signal visualization and structured data recording.\u003c\/p\u003e\n\u003ch2\u003eWhat's Included?\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e1x wireless 4-channel hub\u003c\/li\u003e\n\u003cli\u003eECG sensor\u003c\/li\u003e\n\u003cli\u003eEDA sensor\u003c\/li\u003e\n\u003cli\u003eRIP sensor\u003c\/li\u003e\n\u003cli\u003efNIRS sensor\u003c\/li\u003e\n\u003cli\u003e1x Bluetooth dongle\u003c\/li\u003e\n\u003cli\u003e1x medical-grade charger\u003c\/li\u003e\n\u003cli\u003e24x pre-gelled electrodes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eResources\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/support.pluxbiosignals.com\/wp-content\/uploads\/2021\/10\/biosignalsplux-4-Channel-Hub-Datasheet.pdf\" title=\"biosignalsplux 4-channel hub datasheet with technical specifications (PDF)\"\u003e4-Channel Hub Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/support.pluxbiosignals.com\/wp-content\/uploads\/2021\/11\/biosignalsplux_User_Manual.pdf\" title=\"biosignalsplux user manual with setup and operation instructions (PDF)\"\u003ebiosignalsplux User Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/support.pluxbiosignals.com\/wp-content\/uploads\/2021\/11\/biosignalsplux_Quickstart_Guide.pdf\" title=\"biosignalsplux quickstart guide for initial setup (PDF)\"\u003eBiosignalsplux Quickstart Guide\u003c\/a\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eResearch Evidence \u0026amp; Applications\u003c\/h2\u003e\n\u003cp data-start=\"722\" data-end=\"943\"\u003e\u003cstrong data-start=\"722\" data-end=\"827\"\u003eAttention Classification Based on Biosignals during Standard Cognitive Tasks for Occupational Domains\u003c\/strong\u003e\u003cbr data-start=\"827\" data-end=\"830\"\u003eGamboa, P., Varandas, R., Rodrigues, J., Cepeda, C., Quaresma, C., \u0026amp; Gamboa, H. Published in \u003cem data-start=\"923\" data-end=\"934\"\u003eComputers\u003c\/em\u003e in 2022.\u003c\/p\u003e\n\u003cp data-start=\"945\" data-end=\"1146\"\u003eThe study used PLUX data acquisiton devices to collect physiological data during standard cognitive tasks for attention classification, including ECG, EEG, EDA, fNIRS, RIP and accelerometer data.\u003c\/p\u003e\n\u003cp data-start=\"1148\" data-end=\"1204\"\u003eRead publication \u003ca rel=\"noopener\" title=\"cognitive performance study plux biosignals\" href=\"https:\/\/www.mdpi.com\/2073-431X\/11\/4\/49\" target=\"_blank\"\u003ehere\u003c\/a\u003e.\u003cmeta charset=\"utf-8\"\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003cp data-start=\"6903\" data-end=\"7092\"\u003e\u003cstrong data-start=\"6903\" data-end=\"7007\"\u003ePredicting Driver’s Mental Workload Using Physiological Signals: A Functional Data Analysis Approach\u003c\/strong\u003e\u003cbr data-start=\"7007\" data-end=\"7010\"\u003eBiondi, F. N., Rodriguez, E. F., et al. Published in \u003cem data-start=\"7063\" data-end=\"7083\"\u003eApplied Ergonomics\u003c\/em\u003e in 2024.\u003c\/p\u003e\n\u003cp data-start=\"7094\" data-end=\"7250\"\u003eThe study used biosignalsplux ECG, EMG, EDA and EEG sensors to collect physiological data during simulated driving tasks and predict driver mental workload.\u003c\/p\u003e\n\u003cp data-start=\"7252\" data-end=\"7311\"\u003eRead publication \u003ca rel=\"noopener\" href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/38521001\/\" target=\"_blank\"\u003ehere\u003c\/a\u003e.\u003c\/p\u003e\n\u003chr\u003e\n\u003cp data-start=\"7341\" data-end=\"7512\"\u003e\u003cstrong data-start=\"7341\" data-end=\"7452\"\u003ePhysioLab - A Multivariate Physiological Signal Analysis and Interpretation Toolbox for the Study of Effort\u003c\/strong\u003e\u003cbr data-start=\"7452\" data-end=\"7455\"\u003ePublished in \u003cem data-start=\"7468\" data-end=\"7503\"\u003eMultimedia Tools and Applications\u003c\/em\u003e in 2018.\u003c\/p\u003e\n\u003cp data-start=\"7514\" data-end=\"7677\"\u003eThe study used the biosignalplux toolkit with EDA, ECG and EMG sensors to analyse physiological responses related to effort, cognitive load and physical activity.\u003c\/p\u003e\n\u003cp data-start=\"7679\" data-end=\"7738\"\u003eRead publication \u003ca href=\"https:\/\/doi.org\/10.1007\/s11042-017-5069-z\" rel=\"noopener\" target=\"_blank\"\u003ehere.\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2\u003eFrequently Asked Questions (FAQs)\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat exactly is included in the Cognitive Performance Research Kit?\u003c\/strong\u003e\u003cbr\u003eThe Cognitive Performance Research Kit includes a complete biosignalsplux setup for synchronized physiological data acquisition, based on a 4-channel wireless hub and a predefined set of sensors (ECG, EDA, RIP and fNIRS). \u003cbr\u003eIt also includes all essential and sensor-specific accessories required for proper data acquisition, ensuring a ready-to-use setup without additional system integration.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I access raw physiological data from all sensors?\u003c\/strong\u003e\u003cbr\u003eYes. The kit provides access to raw physiological data from all included sensors.\u003cbr\u003eUsing PLUX software tools, users can visualize and record biosignals in real time, supporting the analysis of physiological and cognitive responses during demanding mental tasks.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs the kit modular or fixed, and can sensors be added or removed?\u003c\/strong\u003e\u003cbr\u003eThe kit is delivered as a predefined configuration, while remaining compatible with the modular biosignalsplux ecosystem. Users can add, remove or replace sensors as needed, with support for up to 4 sensors simultaneously using the included hub.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs this system suitable for both academic and applied research?\u003c\/strong\u003e\u003cbr\u003eYes. The kit is designed to support both academic and applied research in cognitive neuroscience, human factors and performance studies. It can be used in controlled laboratory environments as well as in applied scenarios where cognitive performance and mental workload need to be assessed.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan the system be used for real-time monitoring during cognitive tasks?\u003c\/strong\u003e\u003cbr\u003eYes. The kit supports real-time monitoring of physiological signals during cognitive tasks. Users can visualize signals as they are acquired, enabling immediate observation of responses associated with cognitive load and task demands.\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"PLUX Biosignals","offers":[{"title":"Default Title","offer_id":57335390273861,"sku":null,"price":3396.25,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0595\/1068\/5887\/files\/1800-CognitivePerformanceResearch-00-ProductDetailsPage.jpg?v=1778059782"},{"product_id":"sleep-research-kit","title":"Sleep Research Kit","description":"\u003cp\u003eThe Sleep Research Kit is a ready-to-use physiological monitoring bundle designed for sleep research and technical data collection. It combines a \u003ca href=\"https:\/\/www.pluxbiosignals.com\/products\/8-channel-biosignals-kit\"\u003emulti-channel acquisition hub\u003c\/a\u003e with a predefined sensor configuration to support synchronized acquisition of movement, respiratory, and cardiac-related signals during sleep or rest conditions, enabling the analysis of sleep-related physiological regulation over time. \u003cbr\u003eIt is intended for researchers and engineers with experience in physiological signal acquisition who need a reliable and reproducible setup for sleep experiments, without the overhead of assembling and validating multi-vendor systems. The kit is optimized for laboratory and controlled study environments where data quality and synchronization are essential. \u003cbr\u003eUsers have access to PLUX software for real-time signal visualization, data recording, and inspection, with optional add-ons available for advanced signal processing and analysis workflows.\u003c\/p\u003e\n\u003ch2\u003eWhat's Included?\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e1x wireless 8-channel hub\u003c\/li\u003e\n\u003cli\u003eECG sensor\u003c\/li\u003e\n\u003cli\u003eBVP sensor\u003c\/li\u003e\n\u003cli\u003e2 RIP sensors\u003c\/li\u003e\n\u003cli\u003eEMG sensor\u003c\/li\u003e\n\u003cli\u003eACC sensor\u003c\/li\u003e\n\u003cli\u003e1x Bluetooth dongle\u003c\/li\u003e\n\u003cli\u003e1x medical-grade charger\u003c\/li\u003e\n\u003cli\u003e24x pre-gelled electrodes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eResources\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/support.pluxbiosignals.com\/wp-content\/uploads\/2021\/10\/biosignalsplux-8-Channel-Hub-Datasheet.pdf\" title=\"biosignalsplux 8-channel hub datasheet with technical specifications (PDF)\"\u003e8-channel Hub Datasheet \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/support.pluxbiosignals.com\/wp-content\/uploads\/2021\/11\/biosignalsplux_User_Manual.pdf\" title=\"biosignalsplux user manual with setup and operation instructions (PDF)\"\u003eBiosignalsplux User Manual \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/support.pluxbiosignals.com\/wp-content\/uploads\/2021\/11\/biosignalsplux_Quickstart_Guide.pdf\" title=\"biosignalsplux quickstart guide for initial setup (PDF)\"\u003eBiosignalsplux Quickstart Guide \u003c\/a\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFrequently Asked Questions (FAQs)\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat exactly is included in the Sleep Research Kit?\u003c\/strong\u003e\u003cbr\u003eThe Sleep Research Kit includes a complete biosignalsplux setup for synchronized physiological data acquisition, based on an 8-channel wireless hub and a predefined set of sensors (ECG, BVP, two RIP sensors, EMG and ACC). \u003cbr\u003eIt also includes all essential accessories required for proper data acquisition, enabling a ready-to-use setup for multi-signal monitoring during sleep studies.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I access raw physiological data from all sensors?\u003c\/strong\u003e\u003cbr\u003eYes. The kit provides access to raw physiological data from all included sensors. \u003cbr\u003eUsing PLUX software tools such as Biosignals Studio, users can visualize and record biosignals in real time, supporting the analysis of cardiac, respiratory and movement patterns during sleep.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs the kit modular or fixed, and can sensors be added or removed?\u003c\/strong\u003e\u003cbr\u003eThe kit is delivered as a predefined configuration, while remaining compatible with the modular biosignalsplux ecosystem. Users can add, remove or replace sensors as needed, with support for up to 8 sensors simultaneously using the included hub.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs the system suitable for full-night and extended sleep recordings?\u003c\/strong\u003e\u003cbr\u003eYes. The kit is designed for full-night and extended sleep recordings in controlled study environments. Its wireless setup supports continuous data acquisition over extended periods (up to ~10h depending on configuration), enabling overnight monitoring and analysis of sleep-related physiological activity.\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"PLUX Biosignals","offers":[{"title":"Default Title","offer_id":57335653335365,"sku":null,"price":5970.75,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0595\/1068\/5887\/files\/1800-Sleep-Research-Kit-00-ProductDetailsPage.jpg?v=1778060022"},{"product_id":"cardiorespiratory-research-kit","title":"Cardiorespiratory Research Kit","description":"\u003ch2\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe Cardiorespiratory Research Kit is a ready-to-use physiological monitoring solution designed to study the interaction between cardiac, respiratory, and muscular activity. Built on a \u003ca href=\"https:\/\/www.pluxbiosignals.com\/products\/4-channel-biosignals-kit\"\u003e4-channel acquisition hub\u003c\/a\u003e, it enables synchronized assessment of heart rhythm, breathing patterns, and localized muscle activation in controlled or applied research settings. \u003cbr\u003eWith dual respiratory inductive plethysmography (RIP) sensors, the kit enables separate monitoring of thoracic and abdominal movement, allowing detailed analysis of breathing mechanics and cardiorespiratory coordination. Combined with ECG and EMG acquisition, it supports research in sleep and breathing pattern studies, respiratory training, physical fatigue, and rehabilitation contexts. \u003cbr\u003eThis kit is suited for researchers and professionals in physiology, sleep research, and cardiorespiratory assessment who require synchronized multi-signal monitoring in a structured experimental setup. Real-time visualization and structured data recording are supported through PLUX software.\u003c\/p\u003e\n\u003ch2\u003eWhat's Included?\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e1x wireless 4-channel hub\u003c\/li\u003e\n\u003cli\u003eECG sensor\u003c\/li\u003e\n\u003cli\u003e2x RIP sensor\u003c\/li\u003e\n\u003cli\u003eEMG sensor\u003c\/li\u003e\n\u003cli\u003e1x Bluetooth dongle\u003c\/li\u003e\n\u003cli\u003e1x medical-grade charger\u003c\/li\u003e\n\u003cli\u003e24x pre-gelled electrodes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eResources\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/support.pluxbiosignals.com\/wp-content\/uploads\/2021\/10\/biosignalsplux-4-Channel-Hub-Datasheet.pdf\" title=\"biosignalsplux 4-channel hub datasheet with technical specifications (PDF)\"\u003e4-Channel Hub Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/support.pluxbiosignals.com\/wp-content\/uploads\/2021\/11\/biosignalsplux_User_Manual.pdf\" title=\"biosignalsplux user manual with setup and operation instructions (PDF)\"\u003ebiosignalsplux User Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/support.pluxbiosignals.com\/wp-content\/uploads\/2021\/11\/biosignalsplux_Quickstart_Guide.pdf\" title=\"biosignalsplux quickstart guide for initial setup (PDF)\"\u003eBiosignalsplux Quickstart Guide\u003c\/a\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFrequently Asked Questions (FAQs)\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat exactly is included in the Cardiorespiratory Research Kit?\u003c\/strong\u003e\u003cbr\u003eThe Cardiorespiratory Research Kit includes a complete biosignalsplux setup for synchronized physiological data acquisition, based on a 4-channel wireless hub and a predefined set of sensors (ECG, two Inductive Respiration (RIP) sensors and EMG). \u003cbr\u003eIt also includes all essential accessories required for proper data acquisition, enabling a ready-to-use setup without additional system integration.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan cardiac and respiratory signals be analyzed synchronously?\u003c\/strong\u003e\u003cbr\u003eYes. The kit enables synchronized acquisition of cardiac and respiratory signals. \u003cbr\u003eECG and dual RIP signals are recorded simultaneously, allowing direct analysis of the relationship between heart rhythm and breathing patterns, supporting studies on cardiorespiratory coordination and breathing dynamics.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs the kit suitable for sleep and long-duration monitoring studies?\u003c\/strong\u003e\u003cbr\u003eYes. The kit is suitable for sleep and long-duration monitoring studies. Its wireless design supports continuous data acquisition over extended periods (up to ~10h depending on configuration), enabling applications such as sleep analysis and breathing pattern assessment.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I access raw physiological data from all sensors?\u003c\/strong\u003e\u003cbr\u003eYes. The kit provides access to raw physiological data from all included sensors. \u003cbr\u003eUsing PLUX software tools such as Biosignals Studio, users can visualize and record biosignals in real time, supporting the analysis of cardiac, respiratory and muscular activity.\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"PLUX Biosignals","offers":[{"title":"Default Title","offer_id":57431515955525,"sku":null,"price":3519.75,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0595\/1068\/5887\/files\/1800-Cardiorespiratory-Research-00-ProductDetailsPage.jpg?v=1778060125"},{"product_id":"human-stress-fatigue-research-kit","title":"Human Stress \u0026 Fatigue Research Kit","description":"\u003ch2\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe Human Stress \u0026amp; Fatigue Research Kit is a ready-to-use physiological acquisition solution designed to assess physiological stress and muscular load during physically demanding or repetitive tasks. It enables synchronized monitoring of cardiac, respiratory, electrodermal, and multi-site muscle activity to characterize how the body responds under sustained effort or operational strain. \u003cbr\u003eWith four EMG channels, the kit supports simultaneous recording from multiple muscle groups, allowing detailed analysis of muscle recruitment patterns and localized fatigue. The included Muscle Load add-on derives quantitative indicators of muscular load from EMG signals, supporting the assessment of muscle activity and fatigue over time. \u003cbr\u003eThis kit is suited for researchers and professionals in ergonomics, occupational health, human performance, and fatigue studies conducting laboratory or field-based assessments. PLUX software is available for real-time signal visualization and structured data recording.\u003c\/p\u003e\n\u003ch2\u003eWhat's Included?\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e1x wireless 8-channel hub\u003c\/li\u003e\n\u003cli\u003eECG sensor\u003c\/li\u003e\n\u003cli\u003e4 EMG sensors\u003c\/li\u003e\n\u003cli\u003eRIP sensor\u003c\/li\u003e\n\u003cli\u003eEDA sensor\u003c\/li\u003e\n\u003cli\u003eMuscle Load add-on\u003c\/li\u003e\n\u003cli\u003e1x Bluetooth dongle\u003c\/li\u003e\n\u003cli\u003e1x medical-grade charger\u003c\/li\u003e\n\u003cli\u003e24x pre-gelled electrodes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eResources\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/support.pluxbiosignals.com\/wp-content\/uploads\/2021\/10\/biosignalsplux-4-Channel-Hub-Datasheet.pdf\" title=\"biosignalsplux 8-channel hub datasheet with technical specifications (PDF)\"\u003e8-channel Hub Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/support.pluxbiosignals.com\/wp-content\/uploads\/2021\/11\/biosignalsplux_User_Manual.pdf\" title=\"biosignalsplux user manual with setup and operation instructions (PDF)\"\u003eBiosignalsplux User Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/support.pluxbiosignals.com\/wp-content\/uploads\/2021\/11\/biosignalsplux_Quickstart_Guide.pdf\" title=\"biosignalsplux quickstart guide for initial setup (PDF)\"\u003eBiosignalsplux Quickstart Guide\u003c\/a\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFrequently Asked Questions (FAQs)\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat exactly is included in the Human Stress \u0026amp; Fatigue Research Kit?\u003c\/strong\u003e\u003cbr\u003eThe Human Stress \u0026amp; Fatigue Research Kit includes a complete biosignalsplux setup for synchronized physiological data acquisition, based on an 8-channel wireless hub and a predefined set of sensors (ECG, RIP, EDA and four EMG sensors). \u003cbr\u003eIt also includes all essential and sensor-specific accessories required for proper data acquisition, ensuring a ready-to-use setup without additional system integration.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the Muscle Load Add-on?\u003c\/strong\u003e\u003cbr\u003eThe Muscle Load Add-on provides quantitative indicators of muscular load derived from EMG signals. It enables the analysis of muscle activity and fatigue over time, supporting the assessment of muscle recruitment patterns during sustained or repetitive tasks.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs the kit modular or fixed, and can sensors be added or removed?\u003c\/strong\u003e\u003cbr\u003eThe kit is delivered as a predefined configuration, while remaining compatible with the modular biosignalsplux ecosystem. Users can add, remove or replace sensors as needed, with support for up to 8 sensors simultaneously using the included hub.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs the kit suitable for studies involving participant movement or dynamic tasks?\u003c\/strong\u003e\u003cbr\u003eYes. The kit is designed to support studies involving participant movement and physically demanding or repetitive tasks. \u003cbr\u003eIts wireless design enables physiological data acquisition in mobile scenarios, supporting applications such as ergonomics assessments, occupational studies and performance monitoring under sustained effort.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow can recorded data be exported and used for offline analysis?\u003c\/strong\u003e\u003cbr\u003eRecorded data can be exported using PLUX software tools such as Biosignals Studio, in structured formats suitable for further processing in external analysis tools or custom workflows. \u003cbr\u003eThis enables detailed offline analysis of physiological signals, including muscular load and fatigue over time.\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"PLUX Biosignals","offers":[{"title":"Default Title","offer_id":57437194551621,"sku":null,"price":6135.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0595\/1068\/5887\/files\/1800-Human-Stress-fatigue-Research-00-ProductDetailsPage.jpg?v=1778060238"},{"product_id":"physiological-monitoring-kit","title":"Physiological Monitoring Kit","description":"\u003ch2\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe Physiological Monitoring Kit is a ready-to-use hardware bundle for multi-parameter physiological data acquisition. It combines a biosignalsplux 4-channel hub with a predefined set of sensors, providing a consolidated setup for synchronous recording of physiological signals commonly used in performance and baseline monitoring, both in controlled and applied study settings. This kit is designed for researchers, engineers, and applied science professionals who require a ready-to-deploy solution for physiological data collection in research, development, or field-based studies, while maintaining participant freedom of movement when required by the protocol. It is suited to studies that require monitoring physiological responses to physical effort and workload over time. This allows physiological responses to be analyzed in combination, rather than in isolation. Users can access software for real-time signal visualization and structured data recording, with straightforward data export for offline analysis.\u003c\/p\u003e\n\u003ch2\u003eWhat's Included?\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e1x wireless 4-channel hub\u003c\/li\u003e\n\u003cli\u003eECG sensor\u003c\/li\u003e\n\u003cli\u003eEMG sensor\u003c\/li\u003e\n\u003cli\u003eRIP sensor\u003c\/li\u003e\n\u003cli\u003eTMP sensor\u003c\/li\u003e\n\u003cli\u003e1x Bluetooth dongle\u003c\/li\u003e\n\u003cli\u003e1x medical-grade charger\u003c\/li\u003e\n\u003cli\u003e24x pre-gelled electrodes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eResources\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/support.pluxbiosignals.com\/wp-content\/uploads\/2021\/10\/biosignalsplux-4-Channel-Hub-Datasheet.pdf\" title=\"biosignalsplux 4-channel hub datasheet with technical specifications (PDF)\"\u003e4-Channel Hub Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/support.pluxbiosignals.com\/wp-content\/uploads\/2021\/11\/biosignalsplux_User_Manual.pdf\" title=\"biosignalsplux user manual with setup and operation instructions (PDF)\"\u003ebiosignalsplux User Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/support.pluxbiosignals.com\/wp-content\/uploads\/2021\/11\/biosignalsplux_Quickstart_Guide.pdf\" title=\"biosignalsplux quickstart guide for initial setup (PDF)\"\u003eBiosignalsplux Quickstart Guide\u003c\/a\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFrequently Asked Questions (FAQs)\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat exactly is included in the Physiological Monitoring Kit?\u003c\/strong\u003e\u003cbr\u003eThe Physiological Monitoring Kit includes a complete biosignalsplux setup for multi-parameter physiological data acquisition, based on a 4-channel wireless hub and a predefined set of sensors (ECG, EMG, RIP and TMP). \u003cbr\u003eIt also includes all essential and sensor-specific accessories required for proper data acquisition, ensuring a ready-to-use setup without additional system integration.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I access raw physiological data from all sensors?\u003c\/strong\u003e\u003cbr\u003eYes. The kit provides access to raw physiological data from all included sensors.\u003cbr\u003eUsing PLUX software tools, users can visualize and record biosignals in real time, supporting the analysis of physiological responses to physical effort, workload and recovery.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs the kit modular or fixed, and can sensors be added or removed?\u003c\/strong\u003e\u003cbr\u003eThe kit is delivered as a predefined configuration, while remaining compatible with the modular biosignalsplux ecosystem. Users can add, remove or replace sensors as needed, with support for up to 4 sensors simultaneously using the included hub.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs the kit suitable for studies involving participant movement or dynamic tasks?\u003c\/strong\u003e\u003cbr\u003eYes. The kit is designed to support studies involving participant movement and dynamic tasks. \u003cbr\u003eIts wireless design enables physiological data acquisition in mobile scenarios, making it suitable for applications such as sports performance analysis, functional training and workload monitoring in real-world conditions.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow can recorded data be exported and used for offline analysis?\u003c\/strong\u003e\u003cbr\u003eRecorded data can be exported using PLUX software tools in structured formats suitable for further processing in external analysis tools or custom workflows. This enables detailed offline analysis of physiological responses across performance, fatigue and workload studies.\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"PLUX Biosignals","offers":[{"title":"Default Title","offer_id":57437199434053,"sku":null,"price":3059.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0595\/1068\/5887\/files\/1800-Physiological-Monitoring-00-ProductDetailsPage.jpg?v=1778060882"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0595\/1068\/5887\/collections\/1970-02.jpg?v=1778075881","url":"https:\/\/www.pluxbiosignals.com\/collections\/ready-to-use-biosignal-research-kits.oembed","provider":"PLUX Biosignals","version":"1.0","type":"link"}